Roofs originally built with other insulating materials

Before designing the roof renovation, the present condition of the roof and the scope of damage need to be inspected. Generally roof renovations are initiated when the waterproof layer needs to be renewed. 

When built with other insulation material it is also important to check the status of the existing insulation. If it is dry and seems to function as wished the added insulation can be installed as described in the previous solutions based on stone wool.

If the existing insulation is wet it is recommended to take the current parts away and replace it totally. There are no limitations in mixing different materials in the built up of a flat roof.

More information

> Design and handling instructions

Calculate your required additional insulation for roof using this calculator! The program calculates your insulation profitability with adequate accuracy.

 

 

 

<< Back to roof solutions

<< Back to solutions

Existing structure

  • Substructure: Concrete TT slab /   Profile steel sheet
  • Thermal insulation:
    20 +140 mm EPS /Cork / PUR
  • Waterproof layer:

    Bitumen or plastic based membrane     

Renovation structure             

  • Additional inclination layer: dry expanded clay pellets
  • Additional thermal insulation: PAROC ROS 30g (grooved), PAROC ROB 80
  • New waterproof membrane