Slab insulation is the classical insulation solution in thin rendered applications both in new buildings and renovations. Slab insulation is particularly recommended when
• The surface of the supporting wall structure is uneven.
• Special noise reduction is required
• The supporting wall structure is a timber structure
When insulation thickness is higher than 140 mm we
recommend a lamella insulation solution. It is also
possible to use slab insulation in two layers of Paroc
stone wool especially in a three-layer application. The advantage of this solution is overlapping joints and no cold bridges.
The insulation slabs are fastened to the supporting wall
structure by gluing and by mechanical fasteners.
Mechanical fasteners must always be used in two-layer
insulation applications. Follow system owner's special
instructions! |