Print
EC - Declaration of Conformity
|
 |
 |
 |
 |
 |
|
 |
 |
Short Description Flexible, fire safe stone wool slab with high thermal insulation and sound absorption performance. |
|
 |
 |
Application General-purpose insulation product for thermal, sound and fire insulation in external walls, lofts and floors in all kind of buildings. |
 |
 |
|
 |
 |
Dimensions |
 |
 |
Width x Length |
Thickness |
 |
 |
565 x 1200 mm |
50 - 200 mm |
 |
 |
In accordance with |
In accordance with |
 |
 |
EN 822 |
EN 823 |
 |
 |
Other sizes can be supplied on request. |
 |
 |
|
 |
 |
Packaging |
 |
 |
Package Type |
 |
 |
Plastic Package or Big Pack |
 |
 |
|
 |
 |
Thermal Conductivity |
 |
 |
Lambda, Declared, λD |
In accordance with |
 |
 |
0,037 W/mK |
EN 13162 |
 |
 |
|
 |
 |
Thermal Resistance |
 |
 |
You can calculate the thermal resistance by using the following equation:
RD = d/λD
Thermal resistance values are also presented on a separate table
(See link)
|
|
 |
 |
|
 |
 |
Air Permeability |
 |
 |
Air Permeability, l┴ |
In accordance with |
 |
 |
130 10-6 m2/sPa |
VTT-C/Sr 1967 |
 |
 |
|
 |
 |
Air Flow Resistance |
 |
 |
You can calculate the air flow resistance by using the following equation:
AF = d/A*l
Air flow resistance values are also presented on a separate table
(See link)
|
|
 |
 |
|
 |
 |
Fire Properties |
 |
 |
Reaction to Fire, Euroclass |
In accordance with |
 |
 |
A1
|
EN 13501-1 |
 |
 |
|
 |
 |
Moisture Properties |
 |
 |
Water absorption (short term), Declared, WS |
In accordance with |
 |
 |
1 kg/m2 |
EN 1609 |
 |
 |
Water absorption (long term), Declared, WL(P) |
In accordance with |
 |
 |
3 kg/m2 |
EN 12087 |
 |
 |
Water vapour transmission, Declared MU, MU |
In accordance with |
 |
 |
1 |
EN 12086 |
 |
 |
|
 |
 |
Mechanical Properties |
 |
 |
Tensile Strength (parallel to faces) |
In accordance with |
 |
 |
Fulfills CE-mark requirements |
EN 1608 |
 |
 |
|
 |
 |
Dimensional Stability |
 |
 |
Normal (23°C), Δεi |
In accordance with |
 |
 |
≤1 % |
EN 1604 |
 |
 |
|
 |
 |
Official Documentation |
 |
 |
|
 |
 |
|
 |
 |
|
 |
 |
Designation Code |
 |
 |